Amermec Omnia HL PCM Installation Manual

Browse online or download Installation Manual for Air filters Amermec Omnia HL PCM. Amermec Omnia HL PCM Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ISO 9001 - Cert. n° 0128/4
IHLPCLJ
0711
6887206_01
Omnia HL PC
HL PCM
Ventilconvettore per installazione verticale o orizzontale con depuratore PLASMACLUSTER®
Fancoil for the vertical or horizontal installation with PLASMACLUSTER® purifier
Ventilo-convecteur pour installation verticale ou horizontale avec dépurateur PLASMACLUSTER®
Gebläsekonvektor zur vertikalen oder horizontalen Installation mit Reinigungsapparat PLASMACLUSTER®
Fan coil para instalaciones verticales u horizontales con depurador PLASMACLUSTER®
MANUALE D’USO E INSTALLAZIONE
USE AND INSTALLATION MANUAL
MANUEL D'UTILISATION ET D'INSTALLATION
BEDIENUNGS- UND INSTALLATIONSANLEITUNG
MANUAL DE INSTRUCCIONES E INSTALACIÓN
Sostituisce il - Replace - Remplace le n° - Ersetzt:
6887206_00 / 0503
Page view 0
1 2 3 4 5 6 ... 67 68

Summary of Contents

Page 1 - Omnia HL PC

ISO 9001 - Cert. n° 0128/4IHLPCLJ07116887206_01Omnia HL PCHL PCMVentilconvettore per installazione verticale o orizzontale con depuratore PLASMACLUSTE

Page 2

10CONFIGURAZIONE DIP OMNIA HL CSw 1Dip 1 (Default OFF )Controllo termostatico della temperatura :-funzionamento a Potenza Modulata, OFF-funzionament

Page 3

11AUTOTESTÉ disponibile la funzione Autotest per accertare il funzionamento del ventilconvettore.La sequenza di Autotest è la seguente:1) Selettore (B

Page 4

12INFORMAZIONI IMPORTANTI E MANUTENZIONEIl ventilconvettore è collegato alla rete elettrica ed al circuito idraulico, un intervento da parte di person

Page 5

13DATI DIMENSIONALI [mm]I9342924314921038125911OUTINAttacchi batteria (femmina)Mod. Omnia HL 11 PC Omnia HL 16 PC Omnia HL 26 PC Omnia HL 36 PC1/2”1/

Page 6

14IDATI DIMENSIONALI [mm]DB344====296,514,56,51097450170269138722972CA5326361710762210Mod. HL 11 PC HL 16 PC HL 26 PC HL 36 PCA 640 750 980 1200B 384

Page 7

15SCHEMI DI MONTAGGIO LNOMNIA HL PC - HL PCMI

Page 8 - ROTAZIONE DELLA BATTERIA

16ICAE2CBV1V2V3NPELE66 DipSW max 3mSA max 3mMS max 3mVel.1PEVel.3Vel.2NL}230V / 450VA2A max 3m230V 50HzSCY1Y2230V / 450VA2A max 3m}Y1Y210KM110K2

Page 9 - INSTALLAZIONE DELL’UNITÀ

17PROBLEMAPoca aria in uscitaNon fa caldoNon fa freddoIl ventilatore non giraFenomeni di condensa-zione sulla struttura ester-na dell’apparecchioPROBA

Page 10 - IMPOSTAZIONI DIP-SWITCH

18GBFAN COILS WITH PLASMACLUSTER AIR PURIFIEROMNIA HL PC - HL PCMThe OMNIA HL (High Line) fan coil features anexclusive design produced by the Giugiar

Page 11 - AUTOTEST

BLU25°C17°C33°CROSSO20°C12°C28°C19GBCOMMANDS:Ventilation is only allowed with the finning open, it isnecessary to open it manually. The closure of the

Page 13 - Accessorio ZH

20OPERATIONOMNIA HL PC - HL PCM fancoils are delivered ready tooperate in standard configuration, though can be adjustedby the installation technician

Page 14 - DATI DIMENSIONALI [mm]

21COIL ROTATIONIf the water connection layout makes it necessary to turn thecoil around, first remove the cabinet and then proceed asfollows.a) Discon

Page 15 - OMNIA HL PC - HL PCM

22GBDIPSWITCH P SETTINGDIPSWITCH CONFIGURATIONConfiguration of dipswitches must only be carried out by qualified personnel during unit installation.Al

Page 16

23GBAUTOTEST FUNCTIONThis function is designed to check the operation of the fancoil.To run the Autotest function, proceed as follows:1) Selector swit

Page 17 - PROBLEMI E SOLUZIONI

24GBIMPORTANT MAINTENANCE INFORMATION The fancoil is connected to the power supply and a water circuit. Operations performed by persons without the re

Page 18

25DIMENSIONS [mm]GB9342924314921038125911OUTINCoil connection (female)Mod. Omnia HL 11 PC Omnia HL 16 PC Omnia HL 26 PC Omnia HL 36 PC1/2”1/2”1/2”1/2

Page 19 - (OMNIA HL PC - HL PCM)

26DIMENSIONS [mm]GBDB344====296,514,56,51097450170269138722972CA5326361710762210Mod. HL 11 PC HL 16 PC HL 26 PC HL 36 PCA 640 750 980 1200B 384 494

Page 20 - OPERATION

LN27INSTALLATION DIAGRAMSOMNIA HL PC - HL PCMGB

Page 21 - ELECTRICAL CONNECTIONS

28GBCAE2CBV1V2V3NPELE66 DipSW max 3mSA max 3mMS max 3mVel.1PEVel.3Vel.2NL}230V / 450VA2A max 3m230V 50HzSCY1Y2230V / 450VA2A max 3m}Y1Y210KM110K

Page 22 - DIPSWITCH CONFIGURATION

29PROBLEMFeeble air dischargeIt does not heatIt does not coolThe fan does not turnCondensation on the unitcabinet.PROBABLE CAUSEWrong speed setting on

Page 23 - AUTOTEST FUNCTION

3Informazioni generali • General informationInformations generales • Allgemeine Informationen • Informaciones generales 4Trasporto • Carriage • Transp

Page 24

30FVENTILO-CONVECTEUR AVEC DEPURATEUR D'AIR PLASMACLUSTEROMNIA HL PC - HL PCMLe ventilo-convecteur OMNIA HL (High Line) estcaractérisé par son de

Page 25 - ZH Accessory

BLU25°C17°C33°CROSSO20°C12°C28°C31FCOMMANDES:La ventilation n'est permise qu'avec l'ailette ouverte,il faut l'ouvrir manuellement.

Page 26 - DIMENSIONS [mm]

32CARACTERISTIQUES DE FONCTIONNEMENTLes ventilo-convecteurs OMNIA HL PC - HL PCM sont livrésprêts à fonctionner dans une configuration standard, mais

Page 27

33ROTATION DE LA BATTERIESi pour des motifs de raccordement hydraulique on devaittourner la batterie, après avoir retiré le meuble, procédercomme suit

Page 28 - READING KEY

34FSw 1Dip 1 (Default OFF)Contrôle thermostatique de la température:- fonctionnement à la Puissance Modulée, OFF- fonctionnement à 3 niveaux, ONDip 2

Page 29 - PROBLEM AND REMEDY

35AUTOTESTLa présence de la fonction d'Autotest permet de s'assurer du fonctionnement du ventilo-convecteur.La séquence d'Autotest est

Page 30

36FINFORMATIONS IMPORTANTES SUR LA MAINTENANCELe ventilo-convecteur est connecté au réseau électrique et au circuit hydraulique : l'intervention

Page 31 - TILISATION

37DIMENSIONS [mm]F9342924314921038125911OUTINRaccords batterie (femelle)Mod. Omnia HL 11 Omnia HL 16 Omnia HL 26 Omnia HL 361/2”1/2”1/2”1/2”Mod Omnia

Page 32 - INSTALLATION DE L'UNITE

38DIMENSIONS [mm]FDB344====296,514,56,51097450170269138722972CA5326361710762210Mod. HL 11 PC HL 16 PC HL 26 PC HL 36 PCA 640 750 980 1200B 384 494 72

Page 33 - CONNEXIONS ELECTRIQUES

LN39SCHÉMAS DE MONTAGEOMNIA HL PC - HL PCMF

Page 34 - CONFIGURATION DIP

AERMEC S.p.A.I-37040 Bevilacqua (VR) Italia – Via Roma, 44Tel. (+39) 0442 633111Telefax (+39) 0442 93730 – (+39) 0442 93566www.aermec.com -

Page 35

40FCAE2CBV1V2V3NPELE66 DipSW max 3mSA max 3mMS max 3mVel.1PEVel.3Vel.2NL}230V / 450VA2A max 3m230V 50HzSCY1Y2230V / 450VA2A max 3m}Y1Y210KM110K2

Page 36

41PROBLEMEIl y a peu d’air en sortiePas de chaleurPas de froidLe ventilateur ne tournepasPhénomènes de conden-sation sur la structureexterieure de l’a

Page 37 - Accessorie ZH

42DGEBLÄSEKONVEKTOR MIT LUFTREINIGUNGSGERÄT PLASMACLUSTEROMNIA HL PC - HL PCMDer Gebläsekonvektor OMNIA HL (High Line) istdurch sein vom Studio Giugar

Page 38 - DIMENSIONS [mm]

BLU25°C17°C33°CROSSO20°C12°C28°C43DSTEUERUNGEN:Die Lüftung ist nur bei offener Lamelle möglich, diemanuell geöffnet werden muss.Das Schließen der Lame

Page 39

44FUNKTIONSEIGENSCHAFTENDie Gebläsekonvektoren OMNIA HL PC - HL PCM werdenbetriebsbereit mit Standardkonfiguration geliefert, lassendem Installateur j

Page 40

45UMDREHEN DES WÄRMETAUSCHERSFalls es für den Wasseranschluss erforderlich sein sollte, denWärmetauscher zu drehen, gehen Sie nach Abnahme derVerkeidu

Page 41 - PROBLEME ET SOLUTION

46KONFIGURATION DER DIP - SCHALTEREINSTELLUNG DER DIP - SCHALTERDas Gerät spannungslos schalten.Die Arbeiten sind während der Installation von nachwei

Page 42

47AUTOTESTDie verfügbare Funktion Autotest dient zur Funktionskontrolle des Gebläsekonvektors.Die Autotest - Abfolge ist die folgende:1) Wahlschalter

Page 43

48WICHTIGE HINWEISE UND WARTUNGDer Gebläsekonvektor ist sowohl an das Stromnetz wie auch an die Wasserversorgung angeschlossen; Eingriffe durchPersone

Page 44 - INSTALLATION DER EINHEIT

49ABMESSUNGEN [mm]D9342924314921038125911OUTINAnschlüsse des Warmetäuschers (Innengewinde)Mod. Omnia HL 11 Omnia HL 16 Omnia HL 26 Omnia HL 361/2”1/

Page 45 - ELEKTRISCHER ANSCHLUSS

5TRASPORTO • CARRIAGE • TRANSPORT • TRANSPORT • TRANSPORTE12345635KgNON bagnare • Do NOT wetCRAINT l’humidité • Vor Nässe schützenNO mojarNON lasciare

Page 46

50ABMESSUNGEN [mm]DDB344====296,514,56,51097450170269138722972CA5326361710762210Mod. HL 11 PC HL 16 PC HL 26 PC HL 36 PCA 640 750 980 1200B 384 494

Page 47

LN51EINBAUPLÄNEOMNIA HL PC - HL PCMD

Page 48 - WICHTIGE HINWEISE UND WARTUNG

52DCAE2CBV1V2V3NPELE66 DipSW max 3mSA max 3mMS max 3mVel.1PEVel.3Vel.2NL}230V / 450VA2A max 3m230V 50HzSCY1Y2230V / 450VA2A max 3m}Y1Y210KM110K2

Page 49 - Zubehör ZH

53PROBLEMSchwacher Luftstrom am AustrittKeine HeizungKeine KühlungVentilator Arbeitet nichtKondenswasserbildungam Gerät.MÖGLICHE URSACHEFalsche Geschw

Page 50 - ABMESSUNGEN [mm]

54FAN COIL CON DEPURADOR DE AIRE PLASMACLUSTEROMNIA HL PC - HL PCMEl fan coil OMNIA HL (High Line) se caracterizapor su diseño exclusivo realizado por

Page 51

BLU25°C17°C33°CROSSO20°C12°C28°C55MANDOS:La ventilación es posible sólo con la aleta abierta, esnecesario abrirla manualmente. El cierre de la aleta p

Page 52

56CARACTERÍSTICAS DE FUNCIONAMIENTOlos fan coil OMNIA HL PC - HL PCM están preparados parafuncionar con configuración estándar, pero permiten alinsta

Page 53 - PROBLEM UND ABHILFE

57CONEXIONES ELÉCTRICASATENCION: antes de llevar a cabo ninguna intervención,asegúrese de que la alimentación eléctrica esté desactiva-da.En particula

Page 54

58CONFIGURACIÓN DIP SW 1Dip 1 (Por defecto OFF)Control termostático de la temperatura:-funcionamiento a Potencia modulada, OFF-funcionamiento a 3 niv

Page 55

59AUTOTESTESTA DISPONIBLE LA FUNCION Autotest para comprobar el funcionamiento del fan coil.La secuencia de Autotest es la siguiente:1) Selector (B) e

Page 56 - INSTALACIÓN DE LA UNIDAD

6VENTILCONVETTORE CON DEPURATORE D’ARIA PLASMACLUSTEROMNIA HL PC - HL PCMIl ventilconvettore OMNIA HL (High Line) è caratte-rizzato dal suo design esc

Page 57 - ROTACIÓN DE LA BATERÍA

60INFORMACIONES IMPORTANTES Y MANTENIMIENTOEl fan coil está conectado a la red eléctrica y al circuito hidráulico, una intervención por parte de perso

Page 58 - CONFIGURACIÓN DIP

61DATOS DIMENSIONALES [mm]9342924314921038125911OUTINConexiones batería (hembra)Mod. Omnia HL 11 PC Omnia HL 16 PC Omnia HL 26 PC Omnia HL 36 PC1/2”1

Page 59

62DATOS DIMENSIONALES [mm]DB344====296,514,56,51097450170269138722972CA5326361710762210Mod. HL 11 PC HL 16 PC HL 26 PC HL 36 PCA 640 750 980 1200B 38

Page 60

LN63ESQUEMAS DE MONTAJE OMNIA HL PC - HL PCME

Page 61 - Accesorio ZH

64CAE2CBV1V2V3NPELE66 DipSW max 3mSA max 3mMS max 3mVel.1PEVel.3Vel.2NL}230V / 450VA2A max 3m230V 50HzSCY1Y2230V / 450VA2A max 3m}Y1Y210KM110K2

Page 62 - DATOS DIMENSIONALES [mm]

65ProblemaPoco aire en salidaNo hace calorNo hace fríoEl ventilador no giraFenómenos de condensa-ción en la estructuraexterna del aparatoCAUSA PROBABL

Page 63

VALLE D’AOSTAAOSTAFREDDO SYSTEM di Andrea GhiraldiniCorso Battaglione Aosta, 189 - 11100 Aosta Tel. 0165 361946 - Fax 0165 361946PIEMONTEALESSANDRIA -

Page 65 - PROBLEMAS Y SOLUCIONES

I dati tecnici riportati nella presente documentazione non sono impegnativi.AERMEC S.p.A. si riserva la facoltà di apportare in qualsiasi momentotutte

Page 66

7COMANDI:La ventilazione è consentita solo con la aletta aperta,è necessario aprirla manualmente. La chiusura dell’aletta provoca lo spegnimento della

Page 67

8COLLEGAMENTI ELETTRICIATTENZIONE: prima di effettuare qualsiasi intervento,assicurarsi che l’alimentazione elettrica sia disinserita.In particolare p

Page 68 - GARANZIA DI 3 ANNI

9CARATTERISTICHE DI FUNZIONAMENTOI ventilconvettori OMNIA HL PC - HL PCM sono fornitipronti a funzionare in configurazione standard, ma consen-tono al